Automated cardiac output measurement by spatiotemporal integration of color Doppler data. In vitro and clinical validation.
BACKGROUND: A new Doppler echocardiographic technique has been developed for automated cardiac output measurement (ACOM) that assumes neither a flat flow profile nor collinearity with the scan line, but clinical validation of this method is lacking. METHODS AND RESULTS: In 165 subjects (50 intensive care patients, 10 dobutamine echocardiography patients, and 105 normal volunteers; age, 49.4 +/- 19.3 years; 92 men), ACOM was performed in the left ventricular outflow tract (LVOT), with the color baseline shifted to avoid aliasing. ACOM was also tested in a pulsatile in vitro model. Stroke volume was calculated by double integration of Doppler signals in space (across the LVOT) and in time (through the systolic period), assuming hemiaxial symmetry: integral of integral of pi r v(r,t) dr dt, where v(r,t) is the velocity at a distance r from the center of the LVOT at time t during systole. Stroke volume from ACOM was compared with thermodilution (TD), aortic valve pulsed-wave Doppler (PWAO), and left ventricular echocardiographic (two-dimensional [2D]) methods. There was good correlation between ACOM and PWAO (r = .93). TD (r = .86), and 2D (r = .74), with close agreement seen. ACOM had higher correlation and agreement with TD than did either PWAO (P < .02) or 2D (P < .01). ACOM was also able to track accurately the changes in cardiac output with dobutamine infusion in comparison with PWAO (r = .94). In vitro assessment demonstrated excellent correlation (r = .98, y = 1.0x + 1.94) with little impact of pulse repetition frequency or misalignment up to 30 degrees. Gain dependency was noted but could be optimized by visual inspection of the color image. CONCLUSIONS: Automatic integration of numerical data within color Doppler flow fields is a feasible new method for quantifying flow. It is simpler and faster, requires fewer assumptions, and uses only one apical view. ACOM is a promising new approach to echocardiographic quantification that deserves further study and refinement.[1]References
- Automated cardiac output measurement by spatiotemporal integration of color Doppler data. In vitro and clinical validation. Sun, J.P., Pu, M., Fouad, F.M., Christian, R., Stewart, W.J., Thomas, J.D. Circulation (1997) [Pubmed]
Annotations and hyperlinks in this abstract are from individual authors of WikiGenes or automatically generated by the WikiGenes Data Mining Engine. The abstract is from MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine.About WikiGenesOpen Access LicencePrivacy PolicyTerms of Useapsburg