The world's first wiki where authorship really matters (Nature Genetics, 2008). Due credit and reputation for authors. Imagine a global collaborative knowledge base for original thoughts. Search thousands of articles and collaborate with scientists around the globe.

wikigene or wiki gene protein drug chemical gene disease author authorship tracking collaborative publishing evolutionary knowledge reputation system wiki2.0 global collaboration genes proteins drugs chemicals diseases compound
Hoffmann, R. A wiki for the life sciences where authorship matters. Nature Genetics (2008)
 
 
 

Analysis of higher polyamide-6 oligomers on a silica-based reversed-phase column with a gradient of formic acid as compared with hexafluoroisopropanol.

The analysis of polyamide-6 oligomers and polymer is usually performed with expensive fluorinated alcohols like 2,2,2-trifluoroethanol (TFE) or 1,1,1,3,3,3-hexafluoroisopropanol (HFIP). Formic acid is well known as a mobile phase additive to adjust pH in reversed-phase high-performance liquid chromatography. However, formic acid is seldom used as a modifier to perform gradient elution chromatography on octadecyl-modified silica-based columns. Here we demonstrate the determination of cyclic and linear polyamide-6 oligomers using formic acid as a modifier on an octadecyl-modified silica-based column. This column was shown to be stable for more than 5000 column volumes, even when a mobile phase of 65-95% formic acid in water at a flow of 1 ml/min is applied. With formic acid under the conditions used (65-95% formic acid in water) the oligomers are retained on the column, while the polymer does not precipitate. In comparison, during adsorption and separation with a HFIP gradient, precipitation of the polymer occurs. The implications of the different separation mechanisms, i.e., adsorption vs. precipitation chromatography are discussed. Loadability is shown to be much better with the formic acid system. However, with formic acid as a modifier UV detection below 250 nm is not feasible. The less sensitive evaporative light scattering detector is used to detect the polyamide oligomers in the formic acid phase. In addition it is shown that capillary zone electrophoresis (CZE) with UV-absorbance detection using HFIP is an attractive combination as HFIP is UV-transparent and CZE allows low modifier consumption.[1]

References

  1. Analysis of higher polyamide-6 oligomers on a silica-based reversed-phase column with a gradient of formic acid as compared with hexafluoroisopropanol. Mengerink, Y., van der Wal, S., Claessens, H.A., Cramers, C.A. Journal of chromatography. A. (2000) [Pubmed]
 
WikiGenes - Universities