The world's first wiki where authorship really matters (Nature Genetics, 2008). Due credit and reputation for authors. Imagine a global collaborative knowledge base for original thoughts. Search thousands of articles and collaborate with scientists around the globe.

wikigene or wiki gene protein drug chemical gene disease author authorship tracking collaborative publishing evolutionary knowledge reputation system wiki2.0 global collaboration genes proteins drugs chemicals diseases compound
Hoffmann, R. A wiki for the life sciences where authorship matters. Nature Genetics (2008)
 
 
 
 
 

Malignant gastroduodenal obstructions: treatment by means of a covered expandable metallic stent-initial experience.

PURPOSE: To investigate the technical feasibility and clinical effectiveness of a polyurethane-covered expandable nitinol stent in the treatment of malignant gastroduodenal obstructions. MATERIALS AND METHODS: The stent was constructed in-house by weaving a single thread of 0.2-mm nitinol wire in a tubular configuration and was covered with polyurethane solution by means of a dipping method. With fluoroscopic guidance, the stent was placed in 19 consecutive patients with malignant gastric outlet obstruction (n = 15) or duodenal obstruction (n = 4). All patients had severe nausea and recurrent vomiting, and their obstructions were inoperable. RESULTS: Stent placement was technically successful in all but one patient. After stent placement, symptoms improved in all but one patient, who had another stenosis at the proximal jejunum. One patient with stent placement in the second portion of the duodenum became jaundiced. During the mean follow-up of 11 weeks, stent migration occurred in five patients 1-4 days after the procedure. All patients with stent migration were treated by means of placing a second, uncovered nitinol stent. Two of these five patients showed recurrence of stricture because of tumor ingrowth; they underwent coaxial placement of a third, covered nitinol stent with good results. CONCLUSION: Placement of a polyurethane-covered expandable nitinol stent seems to be technically feasible and effective for palliative treatment of inoperable malignant gastroduodenal obstructions. Stent migration, however, is problematic and requires further investigation.[1]

References

  1. Malignant gastroduodenal obstructions: treatment by means of a covered expandable metallic stent-initial experience. Jung, G.S., Song, H.Y., Kang, S.G., Huh, J.D., Park, S.J., Koo, J.Y., Cho, Y.D. Radiology. (2000) [Pubmed]
 
WikiGenes - Universities