The world's first wiki where authorship really matters (Nature Genetics, 2008). Due credit and reputation for authors. Imagine a global collaborative knowledge base for original thoughts. Search thousands of articles and collaborate with scientists around the globe.

wikigene or wiki gene protein drug chemical gene disease author authorship tracking collaborative publishing evolutionary knowledge reputation system wiki2.0 global collaboration genes proteins drugs chemicals diseases compound
Hoffmann, R. A wiki for the life sciences where authorship matters. Nature Genetics (2008)
 
 
 
 
 

A technique for frameless stereotaxy and placement of transarticular screws for atlanto-axial instability in rheumatoid arthritis.

The aim of the present study was to outline a new surgical technique and describe how, in a clinical setting, computer-generated image-guidance can assist in the planning and accurate placement of transarticular C1/C2 screws inserted using a minimally invasive exposure. Forty-six patients with atlanto-axial instability due to rheumatoid arthritis underwent posterior stabilisation with transarticular screws. This was achieved with a minimal posterior exposure limited to C1 and C2 and percutaneous screw insertions via minor stab incisions. The Stealth Station (Medtronic Sofamor Danek, Memphis, Tenn., USA) was used for image guidance to navigate safely through C2. Reconstructed computed tomographic (CT) scans of the atlanto-axial complex were used for image guidance. It was possible to perform preoperative planning of the screw trajectory taking into account the position of the intraosseous portion of the vertebral arteries, the size of the pars interarticularis and the quality of bone in C2. Screws could be inserted percutaneously over K-wires using a drill guide linked to the image-guidance system. Preoperative planning was performed in all 46 patients and accurate registration allowed proposed screw trajectories to be identified. Thirty-eight patients had bilateral screws inserted and eight had a unilateral screw. A total of 84 screws were inserted using the Stealth Station. There were no neurovascular injuries. This technique for placing transarticular screws is accurate and safe. It allows a minimally invasive approach to be followed. Image guidance is a useful adjunct for the surgeon undertaking complex spinal procedures.[1]

References

  1. A technique for frameless stereotaxy and placement of transarticular screws for atlanto-axial instability in rheumatoid arthritis. Wigfield, C., Bolger, C. European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society. (2001) [Pubmed]
 
WikiGenes - Universities