The world's first wiki where authorship really matters (Nature Genetics, 2008). Due credit and reputation for authors. Imagine a global collaborative knowledge base for original thoughts. Search thousands of articles and collaborate with scientists around the globe.

wikigene or wiki gene protein drug chemical gene disease author authorship tracking collaborative publishing evolutionary knowledge reputation system wiki2.0 global collaboration genes proteins drugs chemicals diseases compound
Hoffmann, R. A wiki for the life sciences where authorship matters. Nature Genetics (2008)
 
 
 
 
 

Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage.

Recently, implant anchors such as titanium screws have been used for absolute anchorage during edgewise treatment. However, there have been few human studies reporting on the stability of implant anchors placed in the posterior region. The purpose of this study was to examine the success rates and to find the factors associated with the stability of titanium screws placed into the buccal alveolar bone of the posterior region. Fifty-one patients with malocclusions, 134 titanium screws of 3 types, and 17 miniplates were retrospectively examined in relation to clinical characteristics. The 1-year success rate of screws with 1.0-mm diameter was significantly less than that of other screws with 1.5-mm or 2.3-mm diameter or than that of miniplates. Flap surgery was associated with the patient's discomfort. A high mandibular plane angle and inflammation of peri-implant tissue after implantation were risk factors for mobility of screws. However, we could not detect a significant association between the success rate and the following variables: screw length, kind of placement surgery, immediate loading, location of implantation, age, gender, crowding of teeth, anteroposterior jaw base relationship, controlled periodontitis, and temporomandibular disorder symptoms. We concluded that the diameter of a screw of 1.0 mm or less, inflammation of the peri-implant tissue, and a high mandibular plane angle (ie, thin cortical bone), were associated with the mobility (ie, failure) of the titanium screw placed into the buccal alveolar bone of the posterior region for orthodontic anchorage.[1]

References

  1. Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage. Miyawaki, S., Koyama, I., Inoue, M., Mishima, K., Sugahara, T., Takano-Yamamoto, T. American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics. (2003) [Pubmed]
 
WikiGenes - Universities