The world's first wiki where authorship really matters (Nature Genetics, 2008). Due credit and reputation for authors. Imagine a global collaborative knowledge base for original thoughts. Search thousands of articles and collaborate with scientists around the globe.

wikigene or wiki gene protein drug chemical gene disease author authorship tracking collaborative publishing evolutionary knowledge reputation system wiki2.0 global collaboration genes proteins drugs chemicals diseases compound
Hoffmann, R. A wiki for the life sciences where authorship matters. Nature Genetics (2008)
 
 
 
 
 

Real-time measurements of dissolved oxygen inside live cells by organically modified silicate fluorescent nanosensors.

Optical PEBBLE (probes encapsulated by biologically localized embedding) nanosensors have been developed for dissolved oxygen using organically modified silicate (ormosil) nanoparticles as a matrix. The ormosil nanoparticles are prepared via a sol-gel-based process, which includes the formation of core particles with phenyltrimethoxysilane as a precursor followed by the formation of a coating layer with methyltrimethoxysilane as a precursor. The average diameter of the resultant particles is 120 nm. These sensors incorporate the oxygen-sensitive platinum porphyrin dye as an indicator and an oxygen-insensitive dye as a reference for ratiometric intensity measurement. Two pairs of indicator dye and reference dye, respectively, platinum(II) octaethylporphine and 3,3'-dioctadecyloxacarbocyanine perchlorate, and platinum(II) octaethylporphine ketone and octaethylporphine, were used. The sensors have excellent sensitivity with an overall quenching response of 97%, as well as excellent linearity of the Stern-Volmer plot (r(2) = 0.999) over the whole range of dissolved oxygen concentrations (0-43 ppm). In vitro intracellular changes of dissolved oxygen due to cell respiration were monitored, with gene gun injected PEBBLEs, in rat C6 glioma cells. A significant change was observed with a fluorescence ratio increase of up to 500% after 1 h, for nine different sets of cells, which corresponds to a 90% reduction in terms of dissolved oxygen concentration. These results clearly show the validity of the delivery method for intracellular studies of PEBBLE sensors, as well as the high sensitivity, which is needed to achieve real-time measurements of intracellular dissolved oxygen concentration.[1]

References

  1. Real-time measurements of dissolved oxygen inside live cells by organically modified silicate fluorescent nanosensors. Koo, Y.E., Cao, Y., Kopelman, R., Koo, S.M., Brasuel, M., Philbert, M.A. Anal. Chem. (2004) [Pubmed]
 
WikiGenes - Universities