The world's first wiki where authorship really matters (Nature Genetics, 2008). Due credit and reputation for authors. Imagine a global collaborative knowledge base for original thoughts. Search thousands of articles and collaborate with scientists around the globe.

wikigene or wiki gene protein drug chemical gene disease author authorship tracking collaborative publishing evolutionary knowledge reputation system wiki2.0 global collaboration genes proteins drugs chemicals diseases compound
Hoffmann, R. A wiki for the life sciences where authorship matters. Nature Genetics (2008)
 
 
 
 
 

Comparison of catheter ablation using radiofrequency versus direct current energy: biophysical, electrophysiologic and pathologic observations.

The effects of catheter ablation with radiofrequency versus direct current energy were compared in 18 dogs assigned to two groups (of 9 dogs each). Each dog underwent a single ablation at two sites in the left ventricle at energy levels of 100, 200 or 300 J delivered in unipolar configuration to six dogs each. A transient decrease in left ventricular systolic pressure (from 121.3 +/- 24.5 to 94.2 +/- 18.7 mm Hg, p less than 0.01) and wall motion abnormality were noted in dogs with direct current shock. The left ventricular ejection fraction decreased (from 50 +/- 2% to 34 +/- 3%, p less than 0.001) shortly after direct current ablation but improved 4 weeks later to 43 +/- 3%. There were no significant changes in left ventricular pressure, wall motion or ejection fraction in dogs in the radiofrequency ablation group. Sustained ventricular tachycardia (greater than or equal to 30 s) was seen immediately after direct current shock in all dogs, and one dog died of intractable ventricular fibrillation. A 24-h ambulatory electrocardiographic (ECG) monitor obtained immediately after the procedure showed multiple runs of ventricular tachycardia in all dogs exposed to direct current ablation but in only three dogs that underwent radiofrequency ablation. No differences were found in peak creatine kinase, complete blood count with smear and B-beta 15-42 fibrinopeptide levels. Pathologically, direct current-induced lesions were larger (mean length x width x depth 10.9 x 7.5 x 5.2 vs. 4.8 x 4.6 x 4.3 mm) and were poorly circumscribed with inhomogeneous margins of necrosis.(ABSTRACT TRUNCATED AT 250 WORDS)[1]

References

  1. Comparison of catheter ablation using radiofrequency versus direct current energy: biophysical, electrophysiologic and pathologic observations. Huang, S.K., Graham, A.R., Lee, M.A., Ring, M.E., Gorman, G.D., Schiffman, R. J. Am. Coll. Cardiol. (1991) [Pubmed]
 
WikiGenes - Universities