The world's first wiki where authorship really matters (Nature Genetics, 2008). Due credit and reputation for authors. Imagine a global collaborative knowledge base for original thoughts. Search thousands of articles and collaborate with scientists around the globe.

wikigene or wiki gene protein drug chemical gene disease author authorship tracking collaborative publishing evolutionary knowledge reputation system wiki2.0 global collaboration genes proteins drugs chemicals diseases compound
Hoffmann, R. A wiki for the life sciences where authorship matters. Nature Genetics (2008)
 
 
 

Fracture behavior of straight or angulated zirconia implant abutments supporting anterior single crowns.

The aim of the study was to evaluate the influence of artificial aging on the fracture behavior of straight and angulated zirconia implant abutments (ZirDesign™; Astra Tech, Mölndal, Sweden) supporting anterior single crowns (SCs). Four different test groups (n = 8) representing anterior SCs were prepared. Groups 1 and 2 simulated a clinical situation with an ideal implant position (left central incisor) from a prosthetic point of view, which allows for the use of a straight, prefabricated zirconia abutment. Groups 3 and 4 simulated a situation with a compromised implant position, requiring an angulated (20°) abutment. OsseoSpeed™ implants (Astra Tech) 4.5 mm in diameter and 13 mm in length were used to support the abutments. The SCs (chromium cobalt alloy) were cemented with glass ionomer cement. Groups 2 and 4 were thermomechanically loaded (TCML = 1.2 × 10⁶; 10,000 × 5°/55°) and subjected to static loading until failure. Statistical analysis of force data at the fracture site was performed using nonparametric tests. All samples tested survived TCML. Artificial aging did not lead to a significant decrease in load-bearing capacity in either the groups with straight abutments or the groups with angulated abutments. The restorations that utilized angulated abutments exhibited higher fracture loads than the restorations with straight abutments (group 1, 280.25 ± 30.45 N; group 2, 268.88 ± 38.00 N; group 3, 355.00 ± 24.71 N; group 4, 320.71 ± 78.08 N). This difference in load-bearing performance between straight and angulated abutments was statistically significant (p = 0.000) only when no artificial aging was employed. The vast majority of the abutments fractured below the implant shoulder.[1]

References

  1. Fracture behavior of straight or angulated zirconia implant abutments supporting anterior single crowns. Nothdurft, F.P., Doppler, K.E., Erdelt, K.J., Knauber, A.W., Pospiech, P.R. Clin. Oral. Investig (2011) [Pubmed]
 
WikiGenes - Universities