The world's first wiki where authorship really matters (Nature Genetics, 2008). Due credit and reputation for authors. Imagine a global collaborative knowledge base for original thoughts. Search thousands of articles and collaborate with scientists around the globe.

wikigene or wiki gene protein drug chemical gene disease author authorship tracking collaborative publishing evolutionary knowledge reputation system wiki2.0 global collaboration genes proteins drugs chemicals diseases compound
Hoffmann, R. A wiki for the life sciences where authorship matters. Nature Genetics (2008)
 
 
 
 
 

Cold pressor thallium-201 myocardial scintigraphy in the diagnosis of coronary artery disease.

Thallium-201 myocardial scintigraphy was performed during cold pressor stimulation in 36 patients aged 36 to 69 years. Thirty-one patients had coronary artery disease and 5 patients did not, as confirmed by coronary cineangiography. Thallium-201 (1.5 to 2 mCi) was injected at 30 seconds of the cold pressor stimulation. The product of systolic pressure X heart rate increased from a baseline of 77.4 +/- 16 (standard deviation [SD]) to 103.6 +/- 17 at 30 seconds of the cold pressor test (p less than 0.0005). Transient perfusion deficits developed in 24 of 31 patients with coronary artery disease (sensitivity 77%), and all 5 patients without coronary artery disease had normal scintigrams. The sensitivity in detecting coronary artery disease was 40% in patients with 1 vessel disease, 91% in patients with 2 vessel disease, and 100% in patients with 3 vessel disease. Exercise electrocardiograms (available in 29 of 36 patients) were positive for ischemia in 18 of 24 patients with coronary artery disease and in 1 of 5 patients without coronary artery disease (sensitivity 75% and specificity less than 80%). Exercise thallium-201 scintigrams, obtained in 16 patients, were positive in 11 patients with coronary artery disease and positive cold pressor thallium-201 scintigrams. Five patients without coronary artery disease and with normal cold pressor thallium-201 scintigrams had normal exercise thallium-201 scintigrams. Coronary cineangiography performed during cold pressor stimulation in 6 patients who had positive cold pressor and exercise thallium-201 scintigrams did not show coronary spasm. Our data indicate that cold pressor thallium-201 scintigraphy offers promise as a noninvasive test in the diagnosis of coronary artery disease and may be used in patients in whom exercise testing is not feasible.[1]

References

 
WikiGenes - Universities