The world's first wiki where authorship really matters (Nature Genetics, 2008). Due credit and reputation for authors. Imagine a global collaborative knowledge base for original thoughts. Search thousands of articles and collaborate with scientists around the globe.

wikigene or wiki gene protein drug chemical gene disease author authorship tracking collaborative publishing evolutionary knowledge reputation system wiki2.0 global collaboration genes proteins drugs chemicals diseases compound
Hoffmann, R. A wiki for the life sciences where authorship matters. Nature Genetics (2008)
 
 
 
 
 

Quantitation of motexafin lutetium in human plasma by liquid chromatography-tandem mass spectrometry and inductively coupled plasma-atomic emission spectroscopy.

Liquid chromatography-tandem mass spectrometry (LC-MS/MS) and inductively coupled plasma-atomic emission spectroscopy (ICP-AES) methods were developed and validated for the evaluation of motexafin lutetium (MLu, lutetium texaphyrin, PCI-0123) pharmacokinetics in human plasma. The LC-MS/MS method was specific for MLu, whereas the ICP-AES method measured total elemental lutetium. Both methods were fast, simple, precise, and accurate. For the LC-MS/MS method, a closely related analogue (PCI-0353) was used as the internal standard (IS). MLu and the IS were extracted from plasma by protein precipitation and injected into an LC-MS/MS system configured with a C18 column and an electrospray interface. The lower limit of quantitation was 0.05 microg MLu mL(-1), with a signal-to-noise ratio of 15:1. The response was linear from 0.05 to 5.0 microg MLu mL(-1). For the ICP-AES method, indium was used as the IS. The sample was digested with nitric acid, diluted, filtered, and then injected into the ICP-AES system. Two standard curve ranges were validated to meet the expected range of sample concentrations: 0.5 to 50, and 0.1 to 10 microg Lu mL(-1). The LC-MS/MS and ICP-AES methods were validated to establish accuracy, precision, analyte stability, and assay robustness. Interday precision and accuracy of quality control samples were < or =6.3% coefficient of variation (CV) and within 2.2% relative error (RE) for the LC-MS/MS method, and < or =8.7% CV and within 4.9% RE for the ICP-AES method. Plasma samples from a subset of patients in a clinical study were analyzed using both methods. For a representative patient, over 90% of the elemental lutetium in plasma could be ascribed to intact MLu at early time points. This percentage decreased to 59% at 48 hours after dosing, suggesting that some degradation and/or metabolism of the drug may have occurred.[1]

References

 
WikiGenes - Universities