The world's first wiki where authorship really matters (Nature Genetics, 2008). Due credit and reputation for authors. Imagine a global collaborative knowledge base for original thoughts. Search thousands of articles and collaborate with scientists around the globe.

wikigene or wiki gene protein drug chemical gene disease author authorship tracking collaborative publishing evolutionary knowledge reputation system wiki2.0 global collaboration genes proteins drugs chemicals diseases compound
Hoffmann, R. A wiki for the life sciences where authorship matters. Nature Genetics (2008)
 
 
 

Closed loop stimulation improves ejection fraction in pediatric patients with pacemaker and ventricular dysfunction.

BACKGROUND: The aim of this prospective study was to evaluate the effect of the closed loop stimulation (CLS) on the ejection fraction in pediatric patients, affected by complete atrioventricular block (CAVB) or CAVB and sinus node dysfunction (SND), with a previously implanted pacemaker (PM) and ventricular dysfunction. The role of electrical therapy in the treatment of pediatric patients with congenital atrioventricular (AV) blocks has been shown. Conventional right ventricular pacing seems to affect ventricular function. Up to now, the feasibility and the long-term results of biventricular pacing in pediatric patients were not entirely clear. METHODS: In eight pediatric patients with a previously implanted single or dual chamber PM, ventricular dysfunction, and CAVB or SND and CAVB, a dual chamber PM INOS(2+)-CLS (Biotronik GmbH, Berlin, Germany) was implanted. The effect of the physiological modulation of CLS pacing mode on the ejection fraction was evaluated by Echo-Doppler examination. Measurements were performed before the substitution of the old PM and for up to 2 years of follow-up. RESULTS: All patients showed correct electrical parameters at implantation and during follow-up. The mean value of the ejection fraction measured before the replacement of the old PM was 36 +/- 7%, while after 2 years it was 47 +/- 1% (P < 0.003). No patient showed any worsening of the ejection fraction, while only one showed no improvement. CONCLUSIONS: DDD-CLS pacing seems to improve ventricular function in pediatric patients with CAVB and/SND in spite of the use of the apical right conventional stimulation.[1]

References

  1. Closed loop stimulation improves ejection fraction in pediatric patients with pacemaker and ventricular dysfunction. Drago, F., Silvetti, M.S., De Santis, A., Fazio, G., Biancalana, G., Grutter, G., Rinelli, G. Pacing. Clin. Electrophysiol (2007) [Pubmed]
 
WikiGenes - Universities