The world's first wiki where authorship really matters (Nature Genetics, 2008). Due credit and reputation for authors. Imagine a global collaborative knowledge base for original thoughts. Search thousands of articles and collaborate with scientists around the globe.

wikigene or wiki gene protein drug chemical gene disease author authorship tracking collaborative publishing evolutionary knowledge reputation system wiki2.0 global collaboration genes proteins drugs chemicals diseases compound
Hoffmann, R. A wiki for the life sciences where authorship matters. Nature Genetics (2008)
 
 
 
 
 

Automated responsiveness test (ART) predicts loss of consciousness and adverse physiologic responses during propofol conscious sedation.

BACKGROUND: The authors evaluated a device designed to provide conscious sedation with propofol (propofol-air), or propofol combined with 50% nitrous oxide (N2O; propofol-N2O). An element of this device is the automated responsiveness test (ART), a method for confirming that patients remain conscious. The authors tested the hypotheses that the ART predicts loss of consciousness and that failure to respond to the ART precedes sedation-induced respiratory or hemodynamic toxicity. METHODS: The protocol consisted of sequential 15-min cycles in 20 volunteers. After a 15-min control period, propofol was infused to an initial target effect-site concentration of 0.0 microg/ml with N2O or 1.5 microg/ml with air. Subsequently, the propofol target effect-site concentration was increased by a designated increment (0.25 and 0.5 microg/ml) and the process repeated. This sequence was continued until loss of consciousness, as defined by an Observer's Assessment of Alertness/Sedation (OAA/S) score of 10/20 or less, or until an adverse physiologic event was detected. RESULTS: The OAA/S score at which only 50% of the volunteers were able to respond to the ART ( P50) during propofol-N2O was 11.1 of 20 (95% confidence interval [CI]: 10.6-11.8); the analogous P50 was 11.8 of 20 (95% CI: 11.4-12.3) with propofol-air. Failure to respond to the ART occurred at a plasma propofol concentration of 0.7 +/- 0.6 microg/ml with propofol-N2O and 1.6 +/- 0.6 microg/ml with propofol-air, whereas loss of consciousness occurred at 1.2 +/- 0.8 microg/ml and 1.9 +/- 0.7 microg/ml, respectively. There were no false-normal ART responses. CONCLUSION: The ART can guide individual titration of propofol because failure to respond to responsiveness testing precedes loss of consciousness and is not susceptible to false-normal responses. The use of N2O with propofol for conscious sedation decreases the predictive accuracy of the ART.[1]

References

  1. Automated responsiveness test (ART) predicts loss of consciousness and adverse physiologic responses during propofol conscious sedation. Doufas, A.G., Bakhshandeh, M., Bjorksten, A.R., Greif, R., Sessler, D.I. Anesthesiology (2001) [Pubmed]
 
WikiGenes - Universities