The world's first wiki where authorship really matters (Nature Genetics, 2008). Due credit and reputation for authors. Imagine a global collaborative knowledge base for original thoughts. Search thousands of articles and collaborate with scientists around the globe.

wikigene or wiki gene protein drug chemical gene disease author authorship tracking collaborative publishing evolutionary knowledge reputation system wiki2.0 global collaboration genes proteins drugs chemicals diseases compound
Hoffmann, R. A wiki for the life sciences where authorship matters. Nature Genetics (2008)
 
 
 

Early clinical results after stentless mitral valve implantation and comparison with conventional valve repair or replacement.

BACKGROUND: A new quadricusp stentless mitral bioprosthetic valve (QMV) is evaluated and compared with current standards. METHODS AND RESULTS: Since August 1997, 67 patients were prospectively evaluated: 23 patients received a QMV, 23 had mitral valve repair (MVR), and 21 received conventional mitral valve replacement ( MVP). Patient age was 69+/-8, 64+/-10, and 62+/-9 years for QMV, MVR, and MVP treatment, respectively. The underlying pathology was mitral stenosis, incompetence, and mixed disease in a corresponding 8, 9, and 6 patients for QMV, 1, 22, and 0 patients for MVR, and 2, 12, and 7 patients for MVP. The papillary muscles were sufficient in all QMV cases to suspend the valve. Cross-clamp time was 59+/-19 minutes for QMV implantation. In-hospital mortality for QMV, MVR, and MVP was 1, 0, and 0 patients, respectively, and thoracotomy had to be performed again in 1, 1, and 2 patients, respectively (these outcomes were not valve related). At baseline transthoracic echocardiography, respective maximum flow velocities were 1.6, 1.4, and 1.7 m/s, and valve orifice area was 2.6, 3.5, and 3.4 cm(2). Mild transvalvular reflux was seen in 8, 7, and 2 patients; moderate reflux, in 1, 1, and 1 patients. Left ventricular ejection fraction was 52%, 54%, and 51% in the respective treatment groups. At follow-up, hemodynamic parameters had further improved in all groups. CONCLUSIONS: One year after clinical implantation, the QMV appears to function well and has no additional risks compared with MVR or MVP. The subvalvular apparatus is preserved by suspending the QMV at the papillary muscles; this arrangement is hemodynamically advantageous. Echocardiography reveals an excellent valve performance that resembles native mitral valve morphology and hemodynamic function. The QMV is a promising alternative for biological mitral valve replacement.[1]

References

  1. Early clinical results after stentless mitral valve implantation and comparison with conventional valve repair or replacement. Walther, T., Walther, C., Falk, V., Diegeler, A., Krakor, R., Schneider, J., Autschbach, R., Mohr, F.W. Circulation (1999) [Pubmed]
 
WikiGenes - Universities