The world's first wiki where authorship really matters (Nature Genetics, 2008). Due credit and reputation for authors. Imagine a global collaborative knowledge base for original thoughts. Search thousands of articles and collaborate with scientists around the globe.

wikigene or wiki gene protein drug chemical gene disease author authorship tracking collaborative publishing evolutionary knowledge reputation system wiki2.0 global collaboration genes proteins drugs chemicals diseases compound
Hoffmann, R. A wiki for the life sciences where authorship matters. Nature Genetics (2008)
 
 
 

Mr flow measurement in the internal mammary artery-to-coronary artery bypass graft: comparison with graft stenosis at radiographic angiography.

PURPOSE: To evaluate the sensitivity and specificity of breath-hold magnetic resonance (MR) flow measurement for detection of significant stenosis in internal mammary artery bypass grafts. MATERIALS AND METHODS: Twenty-six consecutive patients who had undergone coronary artery bypass surgery were examined. Breath-hold velocity-encoded cine MR images were obtained at the midpoint of the internal mammary artery between its origin from the subclavian artery and the distal anastomosis to the left anterior descending artery. RESULTS: MR images were obtained successfully in 24 patients. At conventional angiography, no significant stenosis was observed in 17 patients (group A), and significant stenosis (diameter > 70%) was observed in seven patients (group B). The mean diastolic-to-systolic peak velocity ratio in group B (0.61 +/- 0.44 [SD]) was significantly lower than that in group A (1.88 +/- 0.96; P <.01). Evaluation of graft stenosis with the diastolic-to-systolic peak velocity ratio revealed a sensitivity of 86% and a specificity of 88%. The mean blood flow rate at baseline in group B (16.9 mL/min +/- 5.5) was significantly lower than that in group A (79.8 mL/min +/- 38.2; P <.01). The sensitivity and specificity of MR blood flow measurement in predicting significant stenosis were 86% and 94%, respectively. The mean pharmacologic flow reserve ratios were 2.00 +/- 1.43 in group A and 1.39 +/- 1.46 in group B (P >.05). CONCLUSION: Fast MR blood flow measurement at baseline is highly useful for predicting significant stenosis in internal mammary arterial grafts.[1]

References

  1. Mr flow measurement in the internal mammary artery-to-coronary artery bypass graft: comparison with graft stenosis at radiographic angiography. Ishida, N., Sakuma, H., Cruz, B.P., Shimono, T., Tokui, T., Yada, I., Takeda, K., Higgins, C.B. Radiology. (2001) [Pubmed]
 
WikiGenes - Universities