Interobserver and intraobserver reliability of venous transcranial color-coded flow velocity measurements.
BACKGROUND AND PURPOSE: Venous transcranial color-coded duplex sonography is a new technique for noninvasive evaluation of the intracranial venous system. However, the interobserver and intraobserver reliability of this method is unclear. METHODS: In 23 healthy volunteers (30 +/- 7.3 years of age), the deep middle cerebral vein (dMCV), basal vein (BV), vein of Galen (VG), and straight ( SRS), transverse (TS), and superior sagittal (SSS) sinuses in addition to the arterial segments of the circle of Willis were insonated through the temporal bone window on 2 consecutive days by 2 experienced examiners. The examiners were blinded to each other's results. The interobserver and intraobserver reliability was calculated using a method described by Bland and Altman, resulting in 2-SD confidence intervals. RESULTS: Non-angle-corrected and angle-corrected systolic and end diastolic venous flow velocities (FV) were in good accordance with published normal values, ranging between 8.6 and 19.2 cm/s. The interobserver reliabilities for non-angle-corrected systolic FVs in the dMCV, BV, VG, SRS, and TS were +/- 1.8, 2.4, 2.6, 3.3, and 4.6 cm/s; for angle-corrected systolic FVs, the interobserver reliabilities were +/- 2.5, 3.1, 13.9, 11.6, and 7.7 cm/s. The intraobserver reliabilities for non-angle-corrected systolic FVs in the dMCV, BV, VG, SRS, and TS were +/- 2.9, 3.2, 2.6, 3.2, and 6.1 cm/s; for angle-corrected systolic FVs, the intraobserver reliabilities were 3.2, 3.7, 13.9, 11.6, and 7.5 cm/s. Angle correction was not attempted for the SSS. The interobserver and intraobserver reliabilities for systolic FVs in the SSS were +/- 3.3 and +/- 3.3 cm/s, respectively. CONCLUSIONS: Intracranial venous FVs can be measured with a high interobserver and intraobserver reliability in healthy human subjects. Intraobserver reliability was higher for cerebral veins than for dural sinuses, predisposing them for follow-up examinations; however, angle correction for venous FVs in the VG and the SRS is not advisable.[1]References
- Interobserver and intraobserver reliability of venous transcranial color-coded flow velocity measurements. Stolz, E., Babacan, S.S., Bödeker, R.H., Gerriets, T., Kaps, M. Journal of neuroimaging : official journal of the American Society of Neuroimaging. (2001) [Pubmed]
Annotations and hyperlinks in this abstract are from individual authors of WikiGenes or automatically generated by the WikiGenes Data Mining Engine. The abstract is from MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine.About WikiGenesOpen Access LicencePrivacy PolicyTerms of Useapsburg