The world's first wiki where authorship really matters (Nature Genetics, 2008). Due credit and reputation for authors. Imagine a global collaborative knowledge base for original thoughts. Search thousands of articles and collaborate with scientists around the globe.

wikigene or wiki gene protein drug chemical gene disease author authorship tracking collaborative publishing evolutionary knowledge reputation system wiki2.0 global collaboration genes proteins drugs chemicals diseases compound
Hoffmann, R. A wiki for the life sciences where authorship matters. Nature Genetics (2008)
 
 
 
 
 

Maximum stenosis of extracranial internal carotid artery: effect of luminal morphology on stenosis measurement by using CT angiography and conventional DSA.

PURPOSE: To assess the luminal morphology of the extracranial internal carotid artery at three-dimensional (3D) computed tomographic (CT) angiography and how this factor affects measurement of maximum carotid arterial stenoses at conventional intraarterial digital subtraction angiography (DSA). MATERIALS AND METHODS: Prospectively, conventional intraarterial DSA and 3D CT angiography were performed in 42 carotid arteries in 21 patients with suspected carotid artery disease. The longest axis length-perpendicular axis length (L/P) ratios of the arterial lumen on the cross-sectional images at the most stenotic area and distal nonstenotic area were analyzed by acquiring multiplanar reconstruction (MPR) images at 3D CT angiography. The maximum stenosis was measured at each modality with North American Symptomatic Carotid Endarterectomy Trial criteria. RESULTS: The L/P ratios in the most stenotic areas ranged from 1.0 to 3.2 (mean, 1.5 +/- 0.5 [SD]). The mean difference in maximum percentage of stenosis between the two modalities for L/P ratios of 2.0 or greater was significantly greater than that for L/P ratios of less than 1.5 (P < .05). Three carotid arteries with 70%-99% stenosis, with grades determined only with 3D CT angiography, had L/P ratios of 2.0 or greater. CONCLUSION: On MPR images at 3D CT angiography, the lumen of extracranial internal carotid artery stenosis showed a wide range of shapes. When a carotid artery has a high L/P ratio, the luminal morphology of the carotid artery stenosis may affect the assessment of maximum stenosis of the internal carotid artery at conventional DSA.[1]

References

  1. Maximum stenosis of extracranial internal carotid artery: effect of luminal morphology on stenosis measurement by using CT angiography and conventional DSA. Hirai, T., Korogi, Y., Ono, K., Murata, Y., Takahashi, M., Suginohara, K., Uemura, S. Radiology. (2001) [Pubmed]
 
WikiGenes - Universities