The world's first wiki where authorship really matters (Nature Genetics, 2008). Due credit and reputation for authors. Imagine a global collaborative knowledge base for original thoughts. Search thousands of articles and collaborate with scientists around the globe.

wikigene or wiki gene protein drug chemical gene disease author authorship tracking collaborative publishing evolutionary knowledge reputation system wiki2.0 global collaboration genes proteins drugs chemicals diseases compound
Hoffmann, R. A wiki for the life sciences where authorship matters. Nature Genetics (2008)
 
 
 
 
 

Radiation protection in radionuclide therapies with (90)Y-conjugates: risks and safety.

PURPOSE: The widespread interest in (90)Y internal radionuclide treatments has drawn attention to the issue of radiation protection for staff. Our aim in this study was to identify personnel at risk and to validate the protection devices used. METHODS: (90)Y-MoAb (Zevalin, 15 cases, 1.1 GBq/patient) and (90)Y-peptide ((90)Y-DOTATOC) systemic (i.v., 50 cases, 3.0 GBq/patient) and locoregional (l.r., 50 cases, 0.4 GBq/patient) treatments were considered. Radiolabelling was carried out in a dedicated hot cell. Tele-tongs, shielded (PMMA: polymethylmethacrylate) syringes/vials and an automatic dose fractionating system were used. Operators wore anti-X-ray and anti-contamination gloves, with TLD dosimeters placed over the fingertips. For i.v. administration, activity was administered by a dedicated system; for l.r. administration, during activity infusion in the brain cavity, tongs were used and TLDs were placed over the fingertips. The air kerma-rate was measured around the patients. RESULTS: The use of devices provided a 75% dose reduction, with mean fingertip doses of 2.9 mGy (i.v. MoAbs), 0.6 mGy (i.v. peptides)/radiolabelling procedure and 0.5 mGy/l.r. administration. The mean effective dose to personnel was 5 muSv/patient. The air kerma-rate around the patients administered i.v. (90)Y-peptides were 3.5 (1 h) and 1.0 (48 h) muGy/h at 1 m. Patient hospitalisation of 6 h (l.r.)/48 h (i.v.) guaranteed that the recommended limits of 3 mSv/year to family members and 0.3 mSv/year to the general population (Council Directive 97/43/Euratom) were respected. CONCLUSIONS: When specific procedures are adopted, a substantial improvement in (90)Y manipulation is attainable, reducing doses and increasing safety. For the widespread clinical use of (90)Y-conjugates, a completely automatic labelling procedure is desirable.[1]

References

  1. Radiation protection in radionuclide therapies with (90)Y-conjugates: risks and safety. Cremonesi, M., Ferrari, M., Paganelli, G., Rossi, A., Chinol, M., Bartolomei, M., Prisco, G., Tosi, G. Eur. J. Nucl. Med. Mol. Imaging (2006) [Pubmed]
 
WikiGenes - Universities