Stability of sterile aqueous epinephrine injections submitted by U.S. hospitals.
The stability of sterile aqueous epinephrine injections stored in hospital pharmacies across the United States was studied. Through a voluntary drug stability program, FDA selected 254 samples of epinephrine injection submitted by hospital pharmacies. The samples were analyzed for strength, identification, d-isomer content, related impurities, pH, total acidity, and physical condition. Of the 254 samples tested, 23 samples did not meet USP requirements for epinephrine strength. Four of these samples were still within their expiration dates and seven had no expiration dates, indicating they were manufactured before 1975. An additional 19 samples did not meet USP requirements for total acidity. Some samples were found to be racemic; it appears that the racemic mixture originates from using d,l-epinephrine as the starting material rather than from racemization during shelf-life. Epinephrine injections obtained from hospital pharmacies appear to be stable within their expiration dates.[1]References
- Stability of sterile aqueous epinephrine injections submitted by U.S. hospitals. Kirchhoefer, R.D., Thornton, L.K., Allgire, J.F. American journal of hospital pharmacy. (1986) [Pubmed]
Annotations and hyperlinks in this abstract are from individual authors of WikiGenes or automatically generated by the WikiGenes Data Mining Engine. The abstract is from MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine.About WikiGenesOpen Access LicencePrivacy PolicyTerms of Useapsburg