The world's first wiki where authorship really matters (Nature Genetics, 2008). Due credit and reputation for authors. Imagine a global collaborative knowledge base for original thoughts. Search thousands of articles and collaborate with scientists around the globe.

wikigene or wiki gene protein drug chemical gene disease author authorship tracking collaborative publishing evolutionary knowledge reputation system wiki2.0 global collaboration genes proteins drugs chemicals diseases compound
Hoffmann, R. A wiki for the life sciences where authorship matters. Nature Genetics (2008)
 
 
 

Prevalence of central venous occlusion in patients with chronic defibrillator leads.

BACKGROUND: Many patients with previously implanted ventricular defibrillators are candidates for an upgrade to a device capable of atrial-ventricular sequential or multisite pacing. The prevalence of venous occlusion after placement of transvenous defibrillator leads is unknown. The purpose of this study was to determine the prevalence of central venous occlusion in asymptomatic patients with chronic transvenous defibrillator leads. METHODS: Thirty consecutive patients with a transvenous defibrillator lead underwent bilateral contrast venography of the cephalic, axillary, subclavian, and brachiocephalic veins as well as the superior vena cava before an elective defibrillator battery replacement. The mean time between transvenous defibrillator lead implantation and venography was 45 +/- 21 months. Sixteen patients had more than 1 lead in the same subclavian vein. No patient had clinical signs of venous occlusion. RESULTS: One (3%) patient had a complete occlusion of the subclavian vein, 1 (3%) patient had a 90% subclavian vein stenosis, 2 (7%) patients had a 75% to 89% subclavian stenosis, 11 (37%) patients had a 50% to 74% subclavian stenosis, and 15 (50%) patients had no subclavian stenosis. CONCLUSIONS: The low prevalence of subclavian vein occlusion or severe stenosis among defibrillator recipients found in this study suggests that the placement of additional transvenous leads in a patient who already has a ventricular defibrillator is feasible in a high percentage of patients (93%).[1]

References

  1. Prevalence of central venous occlusion in patients with chronic defibrillator leads. Sticherling, C., Chough, S.P., Baker, R.L., Wasmer, K., Oral, H., Tada, H., Horwood, L., Kim, M.H., Pelosi, F., Michaud, G.F., Strickberger, S.A., Morady, F., Knight, B.P. Am. Heart J. (2001) [Pubmed]
 
WikiGenes - Universities