The world's first wiki where authorship really matters (Nature Genetics, 2008). Due credit and reputation for authors. Imagine a global collaborative knowledge base for original thoughts. Search thousands of articles and collaborate with scientists around the globe.

wikigene or wiki gene protein drug chemical gene disease author authorship tracking collaborative publishing evolutionary knowledge reputation system wiki2.0 global collaboration genes proteins drugs chemicals diseases compound
Hoffmann, R. A wiki for the life sciences where authorship matters. Nature Genetics (2008)
 
 
 

Dialysis filter type determines the acute effect of haemodialysis on endothelial function and oxidative stress.

BACKGROUND: Endothelial function of large arteries is impaired in chronic haemodialysis patients and oxidative stress due to the dialysis procedure has been suggested as a causal factor. However, it is not clear whether different types of dialysis membranes affect endothelial function differently. Therefore we determined endothelium-dependent, flow-mediated dilatation (FMD) of the brachial artery as well as markers of oxidative stress immediately before and after haemodialysis (HD) with either a cellulosic cuprophane or a synthetic polysulphone dialyser in a blinded, randomized, cross-over study. METHODS: Twelve haemodialysis patients (age 55+/-3 years, time on dialysis 20+/-2 months, mean fluid change -1782+/-21 ml, systolic/diastolic blood pressure 139/75 mmHg) were included. Using a multi-gate-pulsed Doppler system (echo-tracking device) brachial artery FMD and nitroglycerine-induced, endothelium-independent vasodilatation (NMD) were measured. Patients were randomized to HD with either a polysulphone or a cuprophane membrane and were crossed over to the other filter. Investigators were blinded to the type of membrane used. Serum concentrations of oxidized LDL (oxLDL) and alpha-tocopherol as markers of oxidative stress were measured before and after each dialysis session. RESULTS: Data are given as mean+/-SEM. Treatment with polysulphone filter HD did not significantly affect FMD (baseline 9.3+/-2.0% vs after HD 9.6+/-1.8%). After dialysis with a cuprophane membrane FMD decreased from 9.4+/-2.1 to 7.4+/-1.8% (P<0.05). NMD was not significantly affected by HD irrespective of the membrane material used. Serum levels of oxLDL were not changed by either treatment; however, alpha-tocopherol concentrations fell significantly after dialysis with the cuprophane filter (baseline 18.0+/-2.3 after HD 16.6+/-1.3 micro g/ml, P<0.05), while alpha-tocopherol levels remained unchanged when the polysulphone membrane was used. CONCLUSIONS: The type of dialysis filter membrane determines the acute effect of haemodialysis on arterial endothelial function. Differences in biocompatibility and oxidative stress may account for the observed differential effects, since the decrease of FMD after dialysis with a cellulosic cuprophane membrane-but not with a synthetic polysulphone membrane-was associated with a reduction in serum vitamin E.[1]

References

  1. Dialysis filter type determines the acute effect of haemodialysis on endothelial function and oxidative stress. Kosch, M., Levers, A., Fobker, M., Barenbrock, M., Schaefer, R.M., Rahn, K.H., Hausberg, M. Nephrol. Dial. Transplant. (2003) [Pubmed]
 
WikiGenes - Universities