A total of 1,020 serum and plasma specimens were tested using the Venereal Disease Research Laboratory (VDRL), Rapid Plasma Reagin (RPR) card, Reagin Screen ( RST) and Fluorescent Treponemal Antibody-Absorption (FTA-ABS) tests. In 257 normal patients, all screening tests were nonreactive; the FTA-ABS test was reactive for one patient. In 588 patients with treated and untreated syphilis, the RST results were 91.7% in agreement with the VDRL and RPR results. In 175 patients with diseases that cause biological false reactions, the RST was 94% in agreement with the other screening tests. The titer of the RST was within one dilution of the corresponding VDRL titer in 91.7% of the 360 speciments tested and within one dilution of the RPR titer in 96.9% of 358 specimens quantitated by both tests.[1]References
- Evaluation of reagin screen, a new serological test for syphilis. Dyckman, J.D., Wende, R.D., Gantenbein, D., Williams, R.P. J. Clin. Microbiol. (1976) [Pubmed]
Annotations and hyperlinks in this abstract are from individual authors of WikiGenes or automatically generated by the WikiGenes Data Mining Engine. The abstract is from MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine.About WikiGenesOpen Access LicencePrivacy PolicyTerms of Useapsburg