The world's first wiki where authorship really matters (Nature Genetics, 2008). Due credit and reputation for authors. Imagine a global collaborative knowledge base for original thoughts. Search thousands of articles and collaborate with scientists around the globe.

wikigene or wiki gene protein drug chemical gene disease author authorship tracking collaborative publishing evolutionary knowledge reputation system wiki2.0 global collaboration genes proteins drugs chemicals diseases compound
Hoffmann, R. A wiki for the life sciences where authorship matters. Nature Genetics (2008)
 
 
 
 
 

High-performance liquid chromatographic determination of N-[2(S)-(mercaptomethyl)-3-(2-methylphenyl)-1-oxopropyl]-L-methionine, the active plasma metabolite of a prodrug atriopeptidase inhibitor ( SCH 42495), using a thiol selective (Au/Hg) amperometric detector.

A high-performance liquid chromatographic assay for the determination of N-[2(S)-(mercaptomethyl)-3-(2-methylphenyl)-1-oxopropyl]-L-methionine ( SCH 42354; II), the active metabolite of the atriopeptidase inhibitor prodrug, N-[2(S)-(acetylthiomethyl)-3-(2-methylphenyl)-1-oxopropyl]-L-methi onine ethyl ester ( SCH 42495; I), in human plasma was validated for use in clinical pharmacokinetic studies. Plasma (200 microliters) was processed by protein precipitation with acetone containing the internal standard, N-[2(S)-(mercaptomethyl)-3-(2-methylphenyl)-1-oxopropyl]-L- ethionine (III). Compound II was recovered (ca. 90%) in the supernatant after centrifugation and prepared for injection by the addition of 0.15 M monochloroacetic acid containing 0.2 mM EDTA. Separation of II and III was accomplished on commercially available reversed-phase C8 columns designed for the separation of basic compounds. Both compounds were detected using amperometric detection (+0.125 V versus Ag/AgCl) on a thin-layer Au/Hg amalgam electrode. The lower limit of quantitation was 10 ng/ml, where the inter-assay precision (coefficient of variation) was +/- 11.4% and the inter-assay accuracy (bias) was +1.0%. No endogenous interferences were observed in the extracts obtained from drug-free plasma. The detector response (using either peak area or height ratios of II to III) was linear from 0.01 to 1.0 micrograms/ml. Compound II was stable in plasma supplemented with EDTA and sodium hydrogensulfite for at least 3 months when stored frozen at -78 degrees C; no significant decomposition of II was observed following three freeze-thaw cycles. The feasibility of this liquid chromatographic assay with electrochemical detection was demonstrated with plasma samples from hypertensive subjects administered 100 mg of compound I.[1]

References

 
WikiGenes - Universities