The world's first wiki where authorship really matters (Nature Genetics, 2008). Due credit and reputation for authors. Imagine a global collaborative knowledge base for original thoughts. Search thousands of articles and collaborate with scientists around the globe.

wikigene or wiki gene protein drug chemical gene disease author authorship tracking collaborative publishing evolutionary knowledge reputation system wiki2.0 global collaboration genes proteins drugs chemicals diseases compound
Hoffmann, R. A wiki for the life sciences where authorship matters. Nature Genetics (2008)
 
 
 
 
 

Carbon dioxide elimination measures resolution of experimental pulmonary embolus in dogs.

Patients with severe pulmonary embolism can suffer progressive hypercapnia refractory to supramaximal mechanical ventilation, and may require open-thoracic or transvenous emergency embolectomy in addition to anticoagulation and/or thrombolysis. The functional recovery of gas exchange would be signaled by an increase in pulmonary CO2 elimination and decrease in CO2 retention; such data could guide the course of operative embolectomy. Accordingly, we studied five chloralose-urethane anesthetized, mechanically ventilated dogs with open thoraces in which the right pulmonary arteries (RPAs) were reversibly occluded with cloth snares. After waiting for steady state, we abruptly released the snare to restore RPA perfusion and experimentally simulate resolution of pulmonary embolism. For 70 min we serially measure the CO2 volume exhaled per breath (VCO2,br), arterial, mixed venous, and end-tidal PCO2 (PACO2, PVCO2, PETCO2), cardiac output (QT), and the alveolar dead space fraction (VDalv/VTalv = [PaCO2 - PETCO2/PaCO2). RPA reperfusion caused VCO2,br to significantly and abruptly increase from 8.9 +/- 2.7 to 11.6 +/- 3.6 mL; 70 min later VCO2,br had returned to baseline. PaCO2 and PVCO2 steadily decreased during 70 min of RPA reperfusion. PETCO2 increased from 25 +/- 5 to 33 +/- 5 mm Hg immediately after RPA reperfusion, as VDalv/VTalv decreased from 54% +/- 10% to 32% +/- 12%, but PETCO2 was still significantly greater than baseline at 70 min of RPA reperfusion. QT did not significantly change. We conclude that intraoperative measurement of VCO2,br should immediately detect and follow the resolution of CO2 retention in the lung and peripheral tissues after RPA reperfusion. PETCO2 could not detect the decrease of VCO2,br back to baseline because PETCO2 does not measure exhaled volume or the PCO2 waveform.[1]

References

  1. Carbon dioxide elimination measures resolution of experimental pulmonary embolus in dogs. Breen, P.H., Mazumdar, B., Skinner, S.C. Anesth. Analg. (1996) [Pubmed]
 
WikiGenes - Universities